Specifications
mA measurement (Measured by clamp)
- Resolution and Range : 0 to 20.99 mA
Accuracy : 0.2% +2 counts
- Resolution and Range : 21.0 mA to 100.0 mA
Accuracy : 1% + 5 counts
- Diameter of measurable conductor : 0.177” or 4.5 mm max
Operating temperature : -10 to 50 ºC
Storage Temperature : -25 to 60ºC
Operating Humidity : < 90% @ <30 ºC, < 75% @ 30 to 55ºC
Operating Altitude : 0 to 2000 m
IP Rating : IP 40
Size : 59 x 38 x 212 mm, (2.32 x 1.5 x 8.35 in.)
Weight : 260G, (9.1 oz.)
Vibration : Random 2 g, 5 to 500 Hz
Shock : 1 meter drop test (except the jaw)
EMI/RFI : Meets EN61326-1
Note: For current measurement w/ JAW, add 1mA to specification for EMC field strengths of 1V/m up to 3V/m.
T
emperature Coefficient : 0.01% ºC (<18? or > 28?)
Power, battery life : (2) AA 1.5 V Alkaline, IEC LR6, 40 hours typical
Warranty
: Three years for electronics
One year for cable and clamp assembly
For
any questions on the warranty, please contact Fluke’s service centre at
1-800-36-FLUKE (1-800-363-5853) or email [email protected]